1. Where is a fusible plug installed on a Scotch or auxiliary boiler?/At or near the center of the crown sheet of the combustion chamber.
2. Fusible plugs are installed in fire-tube boilers to _____________./warn the engineer of low water level
3. If the combustion control system of an automatically fired auxiliary boiler fails to sustain burner ignition after a normal shutdown, you should check for a/an __________./faulty photocell detector
4.Before any work is to be carried out on a burner in an automatically fired auxiliary boiler, you should always _____________./close all manually operated fuel valves
5.Generating tubes in waste heat boilers are finned to ____________./increase the rate of heat transfer
6.If an operating auxiliary boiler has a water pH reading of 7, you should ______________./treat the water with caustic soda
7.Which of the following conditions is responsible for the fuel oil to atomize when using a steam atomizer in an auxiliary boiler?/Expansion of the steam in the furnace.
8.A failure to any component of a flame safeguard control for an automatically fired auxiliary boiler, will result in ______________./the prevention of automatic restart
9.When an auxiliary boiler is on the line, the output of the flame scanner can be checked by placing a microammeter in series with the photoelectric cell circuit. The readings on high fire should be ____________./higher than those at low fire
10.A feed pump for an auxiliary boiler might lose suction if the ____________./feedwater is too hot
11.The water in a steaming auxiliary boiler should be tested daily for ______________./chlorides
12.The programmed control system of an automatic auxiliary boiler will terminate the light off process during the prepurge period if air flow is not sensed and _________./the damper is not sufficiently open
13.The flame safeguard control system of a large automatic auxiliary boiler will provide fuel shut off in the case of high ____________./steam pressure
14.The boiler water alkalinity in a coil-type auxiliary boiler should be maintained at the pH recommended by the boiler manufacturer to _________________./reduce corrosion in the heating coil
15.Coast Guard Regulations (46 CFR) require the controls for automatically fired auxiliary boilers, must be fitted with visible indicators to signal __________./fuel oil shutoff due to flameout
16.When a waste heat boiler is installed in the exhaust of a main propulsion diesel engine, the exhaust gas bypass would be used ____________./at low loads to prevent corrosion in the boiler
17.How is the concentration of dissolved oxygen in the feedwater of an auxiliary boiler maintained at acceptable limits?/Oxygen is liberated by maintaining the highest practical feedwater temperature.
18.Which of the listed types of control systems is required by Coast Guard Regulations (46 CFR) for large automatic auxiliary boiler heating equipment?/All of the above
19.Which of the following items is necessary for all waste heat boiler installations, regardless of design or manufacturer?/Control of evaporation
20.When it becomes necessary to replace any tubes in a water-tube auxiliary boiler to eliminate leaks at the tube seats, the replacement tubes should be ____________./rolled, beaded, and seal welded around the bead edge
21.Automatic combustion control systems for some auxiliary boilers are designed to cycle burners on in response to ____________./low steam pressure
22.It is desirable for an auxiliary boiler safety valve to pop open and reseat quickly to __________./prevent wire drawing of the disc and seat
23.Coast Guard Regulation (46 CFR) requires that after undergoing extensive repairs, an auxiliary boiler, with a maximum allowable working pressure of 60 psig (411.89 kPa), should be hydrostatically tested at a pressure of ______________./90 psig (617.83 kPa)